Model NO.: TMF Series
Measuring Media: Liquid
Measuring Principle: Coriolis Force
Measurement Object: Closed Pipeline
Certification: GB, CE
Measurement Scope: 2kg/H~500t/H
Medium Temperature: -50 ~ +350
Environment Temperature: -20 ~ +70 Degrees Celsius
Measurement Medium: Liquid, Gas, Solid
Power Supply: 24VDC
Density Measurement: Available
Temperature Compensation: Available
Accuracy Class: 0.1%F.S; 0.2%F.S, as Required
Multiple Phase Flow: Available
Media Available: Liquid, Gas
Trademark: Tosilon
Transport Package: International Export Carton Packing, Water Proof
Specification: CE
Origin: Shaanxi
HS Code: 902610000
Tosilon Coriolis Mass Flow Meter for Chemical Liquid / Gas Dosing System (Ex Approved)Design and Manufacturing according to CE, ATEX StandardIntroduction Coriolis Mass Flowmeter measure the force resulting from the acceleration caused by mass moving toward (or away from) a center of rotation. This effect can be experienced when riding a merry-go-round, where moving toward the center will cause a person to have to "lean into" the rotation so as to maintain balance.
As related to flowmeter, the effect can be demonstrated by flowing water in a loop of flexible hose that is "swung" back and forth in front of the body with both hands. Because the water is flowing toward and away from the hands, opposite forces are generated and cause the hose to twist.
General Technical Parameters (For More Details, please contact Tosilon)Measurement Scope Accuracy
2kg/h~500t/h ±0.2%~±0.15%
Work Pressure
(0~32) MPa (in case of other high pressure, it must be of special order)
Medium Temperature Measurement Accuracy
-50 oC~ +350 oC ±1 oC
Environment Temperature
-20 oC ~ +70 oC
Measurement Medium
Liquid, gas, solid, or two phases and three phases mixed fluid
Power Supply
24VDC
Output Signal
4-20mA current signal of flow, with load resistance ≤500Ω
0-10KHz frequency signal of flow.
RS485 Communication protocol
Material of Measuring Pipe Response Time
316L stainless steel 0.1s~5s, adjustable
Explosion-Proof Grade
Ex(ib)II BT2-T5 For more information, please contact Tosilon
Your Global Partner for Automation
www.tosilon.com
Model |
DN |
Measurement scope (t/h) |
Work Pressure(MPa) |
Connection Type (mm) |
TMF-1-5-A |
25 |
0~10 |
0~4 |
Flange 25 |
TMF-1-5-B |
40 |
0~20 |
0~4 |
Flange 40 |
TMF-1-6-A |
50 |
0~30 |
0~4 |
Flange 50 |
TMF-1-6-AB |
65 |
0~50 |
0~4 |
Flange 65 |
TMF-1-6-B |
80 |
0~100 |
0~4 |
Flange 80 |
TMF-1-6-C |
100 |
0~150 |
0~4 |
Flange 100 |
TMF-1-6-D |
150 |
0~300 |
0~2 |
Flange 150 |
TMF-1-6-E |
200 |
0~500 |
0~2 |
Flange 150 |