Suzhou Macxi Fluid Technology Co.,Ltd.
Dom> Blog> Principle and use of vacuum pump spare parts vacuum pump

Principle and use of vacuum pump spare parts vacuum pump

May 19, 2023
Principle and use of vacuum pump spare parts vacuum pump
1. Maximum working pressure of the vacuum pump
The maximum working pressure unit of the vacuum pump is PA, which is the inlet pressure corresponding to the maximum pumping amount. At this pressure, the pump can work continuously without deterioration or damage.
2. Ultimate pressure
The ultimate pressure unit of the pump is PA, which means that the pump is equipped with a standard test hood at the inlet and works according to the specified conditions.
The lowest pressure that tends to be stable without introducing normal gas operation.
3. Pump front pressure
The front pressure unit of the vacuum pump is PA, which is the outlet pressure of the vacuum pump whose exhaust pressure is lower than one atmosphere.
4. Pumping rate of vacuum pump
The unit of pumping rate of the pump is M3/S or L/S, which means that when the pump is equipped with a standard test hood and works according to the specified conditions,
The ratio of the flow of gas flowing through the test hood to the equilibrium pressure measured at the specified location of the test hood. Referred to as the pumping speed of the pump.

5. The starting pressure of the vacuum pump
The starting pressure unit of the vacuum pump is PA, which refers to the pressure at which the pump starts without damage and has a pumping action.

6. Pumping capacity of the vacuum pump
The unit of pumping capacity of the vacuum pump is PA M3/S or PA L/S. Refers to the gas flow at the pump inlet.
7. Maximum front pressure of the vacuum pump
The maximum front pressure unit of the vacuum pump port is PA, which means that the pressure of the front stage that can damage the pump is exceeded.
8. Water vapor allowable amount
The allowable unit of water vapor is KG/H, which refers to the mass flow rate of water vapor that the pump can remove during continuous operation under normal environmental conditions.
9. Compression ratio
The compression ratio is the ratio of the outlet pressure of the pump to a given gas and the inlet pressure.
10. Ho's coefficient
The ratio of the actual pumping speed over the pumping passage area to the theoretical pumping speed calculated at the molecular effluent.
11. Pumping speed coefficient
The ratio of the actual pumping speed of the pump to the theoretical pumping speed at the pump inlet as calculated by the molecular effluent.
12. Return flow rate
The pump's return flow rate unit is G/CM2.S. It refers to the mass flow rate of the pump flow per unit area through the pump inlet when the pump is operated under specified conditions.

13. Maximum allowable water vapor inlet pressure
The maximum allowable water vapor inlet pressure unit is PA. It refers to the highest inlet pressure of water vapor that can be pumped out during continuous operation under normal environmental conditions.

Combal Us

Autor:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

Wszystkie produkty
Możesz też polubił
Powiązane kategorie

Wyślij je do tym dostawcy

Przedmiot:
Email:
wiadomość:

Twoja wiadomość MSS

Combal Us

Autor:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

Wszystkie produkty

Dom

Product

Whatsapp

O nas

Zapytanie

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Wysłać