May 28, 2022

Pump noise control technology and pump noise reduction scheme, Shenzhen Quelte Sound and Noise Reduction Engineering Technology Co., Ltd. specializes in pump noise control and pump noise reduction and noise reduction.

The pump noise is mainly the aerodynamic noise generated by the gas / liquid during the transportation process, the structural noise excited by the vibration of the motor casing, the noise generated by the vibration of the machine base, and the noise of the motor. Such noise level peaks are mainly concentrated in the low octave band, which is in the range of approximately 100-450 Hz . The sound source is a steady-state noise when the pump room is operating normally. Pipeline noise is the noise generated when water flows through a pipe. In addition, the cavitation phenomenon of the pump and the water hammer phenomenon of the pump can also generate instantaneous noise. The noise generated by the water supply pipe is affected by the flow rate and pressure.

The noise generated by the whole set of pumping facilities is mainly mechanical noise. At present, the method of controlling noise in acoustic principle is more commonly used to control the transmission of noise, mainly including sound insulation, sound absorption and noise reduction. Sound insulation is to separate the sound source from the sound receiving point by using sound insulation structure; sound absorption is to use noise absorption structure or sound absorption material to reduce noise; noise reduction is to use impedance, resistance, porous diffusion and other principles to reduce the noise value.

Noise control measures should make full use of the site environment and conditions based on acoustic principles. Such as:

1. According to the pump room environment, the pump room with the sound source is not tightly sealed shall be soundproofed, and the room where the pump room generates noise shall be treated with sound absorption / sound insulation, and the doors and windows shall be soundproofed.

2. Control the noise generated by machine equipment and equipment parts. The pump base of the new pump house should be of heavy weight to prevent vibration from generating noise. Moreover, a rubber vibration isolating pad should be provided for vibration isolation to reduce vibration noise; each pump unit is separately provided with a foundation to prevent resonance. Use soft coupling as much as possible on the pump suction and pressure water pipes . Regular maintenance, problems such as water leakage, loose parts, equipment parts, mechanical vibration, etc. should be repaired in time to reduce noise.

Because different manufacturers and types of pumps, the working principle and structure will be different, so the site survey and analysis of the noise source is very important for the pump room noise reduction scheme design and material selection.

Shenzhen Quelte Sound and Noise Reduction Engineering Technology Co., Ltd. is an engineering technology company specializing in pump noise control and pump noise reduction and noise reduction. It integrates product development, design, acoustic solutions and construction, and specializes in low frequency noise of pump house. and comprehensive management of research and vibration to pump noise, noise control equipment for different types of pumps and pump house, to provide users with on-site noise surveys, analysis, provided the system pump room noise solutions and construction services.

Main business:

Civil use: Noise reduction in residential quarters and residential houses , noise control in pump house, noise control in air conditioning systems, noise control in generator rooms, noise control in power distribution rooms, noise control in transformer rooms, noise control between machinery and equipment , hotel, office and office space Acoustic noise reduction , acoustic design and construction of functional buildings such as conference centers, concert halls, stadiums, and theaters.

Industry: noise control of mechanical equipment, noise reduction, noise reduction , noise reduction of medical equipment, noise reduction, noise reduction of workshops, sound insulation and noise reduction, noise reduction of fan room, noise reduction of air compressor room , equipment production line noise reduction and other production equipment noise and environmental noise control in the plant area, sound insulation, shock absorption, noise reduction and other comprehensive noise control projects. All kinds of sound insulation doors, sound insulation windows, sound insulation rooms, sound insulation covers, sound insulation screens and other sound insulation projects.

'Reducing pump noise method, pump noise control technology, pump damping scheme
Skontaktuj się z nami

Author:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

Wszystkie produkty
You may also like
Related Categories

Wyślij je do tym dostawcy

Przedmiot:
Email:
wiadomość:

Your message must be betwwen 20-8000 characters

Skontaktuj się z nami

Author:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

Wszystkie produkty

Dom

Product

Whatsapp

O nas

Zapytanie

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Wysłać