Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No: I0.60T40W
Marka: Macxi
Orzecznictwo: Ce
Power Source: Electric
Place Of Origin: Jiangsu, China
Customized Support: Oem, Odm, Obm
Structure: Gear Pump
Brand Name: Macxi
Outlet Size: G1/8
Horsepower: 40 W
Power: 40 W
Ambient Temperature: -40℃-70℃
Pressure: 4 Bar
Voltage: 24 V
Warranty: 1 years, 20000 hours
Motor: Built in drive DC brushless
Gear Material: Tungsten Steel
Fluid Viscosity: 0.2-1500cps
Model Number: I0.60T40W
Speed: 500 - 5000 rpm
Flow Rate: 0.60 ml/rev
Pump Body Material: SS with Titanium nitride coating
Podanie: Automotive Industry, Developing World Water Solutions, Drinking water treatment, Food and Beverage Industry, Industrial Utilities, Irrigation and Agriculture, Pharmaceutical industry, temperature control, Wastewater Transport and Flood Control
Packaging: Standardowy karton eksportowy z znakiem wysyłki klientów
wydajność: 50000/year
transport: Land,Ocean,Air
Place of Pochodzenia: Jiangsu, Chiny
Wsparcie: 30000 Piece/Pieces per Year
Certyfikat: ISO 9001
Código HS: 8413609090/8443992990/8413910000
Porta: Shanghai
Rodzaj płatności: T/T
Incoterm: FOB,CFR,EXW
Opis modelu produktu
Instrukcja produktu:
1,400 Filtr siatki należy zainstalować na wlocie pompy przekładniowej.
2. Ta pompa przekładni jest odpowiednia do ciągłej pracy przez długi czas i nie można jej stosować pod warunkiem częstego uruchomienia i zatrzymania.
3. Przed użyciem, wciśnij niewielką ilość medium, aby smarować bieg z wlotu pompy przekładni.
Instrukcja wyboru modelu produktu :
Pump Head |
Motor |
||
I |
0.07 |
S |
40W |
"I" means the Integrated Structure |
Pump revolution, Unit: ml/rev, note ① for details |
Pump body materials, note ② details |
Motor type and Power |
Uwagi:
1. Objętość wyjściowa pompy: 0,07,0,15,0,3,0,6,0,9,1,1,5,3,0,6. 6.
2. „S” oznacza, że materiał ciała pompowy to 316L, zębate i rękawa wałka są zerknięcie, uszczelnienie z PTFE, pozostałe pozostałe to 316L.
„T” oznacza, że materiał ciała pompowy to 316L, przekładnia i wałek to stal wolframowa, rękaw wałowy to podglądanie, uszczelnienie z PTFE, pozostałe pozostałe to 316L.
„P” oznacza, że materiał ciała pompowy to PPS, przekładnia maciela i rękaw wałka są zerkające, uszczelnienie z ffkm, reszta pozostała Hastelloy.
„H” oznacza, że materiały do nadwozia pompy to Hastelloy, zębate i wałka to oku, materiały uszczelniające to PTFE, reszta materiału przepływu pompy to Hastelloy, wygląd i rozmiar jest taki sam 316L Głowica pompy.
Model produktu: I0.60T40W
Schemat produktu:
Parametry produktu:
Pump Model |
Motor Type |
L1(mm) |
L2(mm) |
Pressure(bar) |
Weight(kg) |
Rated Current(A) |
Imp.&Exp. Size |
Flow(L/H) |
I0.15T |
40W |
95.4 |
32.8 |
8 |
0.73 |
2.5 |
G1/8 |
4.5~45 |
I0.30T |
95.4 |
32.8 |
0.73 |
9~90 |
||||
I0.60T |
95.8 |
36.9 |
4 |
0.74 |
18~180 |
|||
70W |
108.1 |
36.9 |
8 |
0.89 |
3.3 |
18~180 |
Pump Head Parameters |
Motor Parameters |
Motor wiring definition |
|||
Fluid Viscosity |
0.2-1500cps |
Drive Type |
Built in drive DC brushless |
Red |
+24V |
AAmbient TemperAture |
-40℃-70℃ |
Rated Voltage |
24V |
Black |
0 |
Static sealing |
PTFE |
Speed regulating voltage |
0-5 (0.35V ON 0.3V OFF) |
Brown |
Speed control signal 0-5V input |
Pump Body |
Stainless steel with Titanium nitride coating |
Speed rpm |
500-5000rpm |
Blue |
5V level, square wave, 2 pulses per revolution |
Gear |
Gear and gear shaft are WC |
Working system |
Continuous |
|
|
Uwagi:
Usługa OEM jest dostępna zgodnie z Twoim żądaniem.
Specyfikacje są tylko w celach informacyjnych, aby sprawdzić szczegóły, prosimy o kontakt.
(Number of phase) |
N |
3 |
(Rated Voltage) |
VDC |
24(8-30VDC) |
(Rated Power) |
W |
40W |
(Speed regulating voltage) |
VDC |
0-5 (0.35V ON 0.3V OFF) |
(Range of speeds) |
RPM |
500-5000 |
(Maximum current) |
A |
2.2A |
(Instantaneous protection current) |
A |
5A |
Instrukcje okablowania
Red |
+24VDC |
Black |
GND |
Brown |
Speed control signal 0-5V input |
Blue |
5V level, square wave, 2 pulses per revolution |
Bezpieczne funkcje
Ochrona operacji: Gdy prąd działający silnik osiągnie prąd graniczny 2,2a, napęd silnikowy rozpocznie ochronę i przestanie działać.
Zablokowana ochrona wirnika: Po zablokowaniu korpusu pompy napęd rozpocznie funkcję ochrony i odciąłby wewnętrzny zasilanie silnika.
Oprogramowanie / sprzęt Ochrona nadmierna prąd: Gdy system wykryje, że natychmiastowy prąd oprogramowania i sprzętu wewnątrz silnika jest większy niż 5a, dysk rozpocznie ochronę.
Ochrona błędów w hali: Gdy awaria czujnika Hall Motor, silnik rozpocznie ochronę, aby zatrzymać się, aby zapobiec spalaniu silnika.
Zgodnie z ochroną napięcia: Gdy napięcie robocze jest niższe niż określony zakres, zatrzyma działanie.
Dane o wydajności
Uwaga: drzwi zaworu są w pełni otwarte i testowane w warunkach bez obciążenia
Uwaga: drzwi zaworu są blokowane i testowane pod Cull Lad Conditio
Kategorie o produkcie : Zintegrowana pompa biegów > 0,60 ml/rev pompę biegów
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.